Back to Top

1
Hi, Guest!
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.
  • MITECH ULTRASONIC FLAW DETECTOR MFD500B

MITECH ULTRASONIC FLAW DETECTOR MFD500B

Update Terakhir
:
20 / 10 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail MITECH ULTRASONIC FLAW DETECTOR MFD500B

Product Overview

 Based on ultrasonic principle, digital ultrasonic flaw detector MFD500B with 320*240 TFT LCD, it can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpieces interior swiftly and accurately without any destruction. It can be used in Laboratory as well as in engineering filed. With range of 0-9999mm, it can meet the requirement for general defect inspection in manufacturing industry, metallurgical industry, metal processing industry, chemical industry and so on. Low power design with large capacity and high performance lithium battery module, it can be long standby for months. High quality with low price, it is the first choice for the practical economic model for ultrasonic testing equipment.

Technical Parameters

l  Range:       0 to 9999mm, at steel velocity

l  Material Velocity: 300 to 15000m/s

l  Display Delay: -20 to 3400 µs

l  Probe Delay/Zero Offset : 0 to 99.99µs

l  Sensitivity Leavings:>60dB (flat-bottomed deep hole 200mmФ2)

l  resolution :>40dB (5P14)

l  Noise Level: ≤ 8%

l  Test Modes: straight ,angle, dual element and thru-transmission

l  Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz

l  Pulse Energy: Low (300V), Medium (500V) and High (700V) spike pulse.

l  Damping: 100Ω, 200Ω and 400Ω

l  Bandwidth (amplifier bandpass ): 0.5 to 15MHz

l  Gate Monitors: Two independent gates controllable over entire sweep range

l  Rectification: Positive half wave, negative half wave, full wave, RF

l  System Linear Error: Horizontal: +/-0.1% FSW, Vertical: 0.25% FSH, Amplifier Accuracy +/-1 dB.

l  Reject (suppression): 0 to 80% full screen height

l  Units: Inch or millimeter

l  Transducer Connections: BNC or LEMO

l  Power Requirements: AC Mains 100-240 VAC, 50-60 Hz

l  Overall Dimensions:263H×170W×61D mm

l  Relative Humidity:(20 ~ 95)% RH

l  Power Supply:DC 9V

l  Operating Temperature: -10℃ to 50℃

l  Storage Temperature: -30℃ to 50℃

Features

Display

Hi-resolution (320×240 pixels) full digital TFT LCD with adjustable brightness, it is capable of providing high contrast viewing of the waveform from bright, direct sunlight to complete darkness.

The hi-resolution TFT LCD display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.

Range

Up to 6000 mm in steel; range selectable in fixed steps or continuously variable, suitable for use on large work pieces and in high-resolution measurements.

Pulse

Pulse Energy selectable among Low (300V), Medium (500V) and High (700V)

Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments

Damping selectable among 100Ω, 200Ω and 400Ω for optimum probe performance

Test Modes including Straight, Angle, Dual and Thru-transmission

Receiver

Sampling10 digits AD Converter at the sampling speed of 160 MHz

RectificationPositive Halfwave, Negative Halfwave, Fullwave and RF

Analog Bandwidth: 0.5MHz to 15MHz capability with selectable frequency ranges (automatically set by the instrument) to match probe for optimum performance.

Gain0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked

Gates

Two fully independent gates offer a range of measurement options for signal height or distance using peak triggering.

The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.

Gate Start: Variable over entire displayed range

Gate Width: Variable from Gate Start to end of displayed range

Gate Height: Variable from 0 to 99% Full Screen Height

Alarms: Threshold positive/negative

Memory

Memory of 100 channel files to store calibration set-ups

Memory of 1000 wave files to store A-Scan patterns and instrument settings.

All the files can be stored, recalled and cleared.

Video Recorder 

Screen scenes can be captured as movie files. About 2 minutes movie can be saved to the inside memory. They can be re-played using the instrument or the PC software delivered with the instrument.

Video Recorder is useful in many situations, convenient for those who want to analyze the probing activities later.

Functions

l  Semiautomatic two point calibration: Automated calibration of transducer zero offset and/or material velocity

 

Real Time Clock

The instrument clock keeps running tracking the time.

Communication

High Speed USB2.0 Port

The DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.

Battery

Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh  

8 hours nominal operating time depending on display brightness

8-10 hours typical recharge time

Knob

Operating adjustments are easily and quickly made using the rotary knob.

 

 

 

 

Tampilkan Lebih Banyak
Kontak Kami