Product Description
- Innovative Multhimeters with current measurements up to 120A AC/DC
- Unique Open Jaw technology for AC/DC current measurements
- Very compact and as reliable as a tradictional full size multimeter
Specification
DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 – 400Hz) DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A) AC A 60.00/120.0A
±2.0%rdg±5dgt (45 – 65Hz) Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ) Continuity buzzer Buzzer sounds below 35±25Ω Diode test 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt Frequency (AC A) 100/400Hz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (400Hz) (DC A) 100/1000Hz/10/100/300.0kHz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz) (Input sensitivity
Current: more than 6A
Voltage: more than 6V [- 10kHz]/more than 20V [10k – 300kHz]) Conductor size Ø12mm max. Withstand voltage 3540V AC for 5 seconds Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326 Power source R03 (1.5V) × 2 * Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes) Dimensions 128 (L) × 92 (W) × 27 (D) mm Weight 220g approx. (including batteries) Accessories R03 (1.5V) × 2, Instruction manual Optional 9107 (Carrying case [Soft])