Back to Top

1
Hi, Guest!
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.
  • KYORITSU 6300

KYORITSU 6300

Update Terakhir
:
04 / 03 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail KYORITSU 6300

KYORITSU 6300 Keterangan • All necessary Power Measurements : V, A, W, VA, Var, Wh, VAh, Varh, cos¸ , In, Hz. • Recording function with " integration time " selectable from 1 second to 1 hour. • Internal non volatile Memory for non-stop recording up to 10 days. • Accepts Removable Compact Flash Memory up to 128MB for non-stop recording up to 5 years. • Supplied with interface software for downloading data to PC via USB. • Four wiring con.gurations : 3 Phase 4 Wires, 3 Phase 3 Wires, single Phase 3 Wire and 2 Wires. • Wide screen with back light Multi-Display system for simultaneous measurements. • Double power supply system : from AC Line and from Alkaline battery with approx. 7 hours of battery life. • Demand function for Energy-Saving measurements. • Designed to Safety Standard IEC 61010-1 CAT.III 600V. 12 kinds of power measurements Voltage ( RMS) , Current ( RMS) , active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor ( cos ¸ ) , frequency , demand measurement, current flowing on the neutral line ( Only on3 phase 4 wire measurement) Regenerative electric power can be measured Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated by private power generator, and is supplied to electric power company. The electric power and the power factor for each phase can be confirmed Monitoring of operation for each phase. Recording internal can be set between 1 second and 1 hour 1/ 2/ 5/ 10/ 15/ 20/ 30 second/ seconds 1/ 2/ 5/ 10/ 15/ 20/ 30 minute/ minutes 1 hour Demand measurement Buzzer sounding and backlight blinking give warning not to exceed the pre-setting demand target value. Double power supply system AC line and Alkaline size AA battery LR6 : 6 pcs. Continuous 7 hours can be measured by using batteries Display 3 different data simultaneously on large screen. 4 types wiring system 1 phase - 2 wire ( 1ch) ( 2ch) , ( 3ch) 1 phase - 3 wire 3 phase - 3 wire 3 phase - 4 wire Direct communication with PC by USB connection The interface for compact flash card ( CF card) is equipped. An external memory up to 1GB or less can be used. Demand Function Measurements and parameters : Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, * Reactive energy, Power factor ( cos ¸ ) , Neutral current, Frequency meter. Wiring connections : 1P 2W, 3P 4W, 3P 3W, 1P 3W Voltage : Ranges [ RMS] : 150 / 300 / 600V ( CF: 2.5 or less) Allowable input : 10~ 110% of each range Display ranges : 5~ 120% of each range Accuracy : ± 0.3% rdg± 0.2% f.s. ( sine wave, 45~ 65Hz) Current : Ranges [ RMS] : 8128 ( 50A type ) : 5 / 10 / 20 / 50A 8127 ( 100A type ) : 10 / 20 / 50 / 100A 8126 ( 200A type ) : 20 / 50 / 100 / 200A 8125 ( 500A type ) : 50 / 100 / 200 / 500A 8124 ( 1000A type ) : 100 / 200 / 500 / 1000A 8129 ( 3000A type ) : 1000 / 3000A ( CF: 3.0 or less. 90% or less of each range) Allowable input : 10~ 110% of each range Display ranges : 1~ 120% of each range Accuracy : ± 0.3% rdg± 0.2% f.s. + Accuracy of Clamp sensor ( sine wave, 45~ 65Hz) Activa power accuracy : ± 0.5% rdg± 0.2% f.s. + Accuracy of Clamp sensor ( Power factor 1, Sine wave, 45~ 65Hz) Frequency meter range : 40~ 70Hz Frequency meter accuracy : ± 3dgt Effect of power factor : Active power : ± 1.0% rdg cos ¸ = ± 0.5 ( PF= 1) Integration time for recording function : 1/ 2/ 5/ 10/ 15/ 20/ 30 Seconds 1/ 2/ 5/ 10/ 15/ 20/ 30/ 60 Minutes Display update period : 1 second Operating temperature and humidity ranges : 0~ + 50º C, less than 85% RH ( without condensation) Storage temperature and humidity ranges : -20~ + 60º C, less than 85% RH ( without condensation) Over load protection : ' Voltage : 720V AC rms Current : 600A AC rms ( with Clamp sensor MODEL 8125) PC communication Interface : USB CF card Interface : Compact flash card ( Standard type 32/ 64/ 128/ 256/ 512MB/ 1GB) Safety standard : IEC 61010-1 CAT.III 600V Power supply : AC Line : 100~ 240V± 10% ( 50/ 60Hz) DC Battery 9V : LR6× 6( Battery life approx. 7h) Power consumption : 10VA ( MAX) Dimension : 175( L) × 120( W) × 65( D) mm Weight : Approx. 800g ( including batteries) Accessories : 7141 ( Test Lead : 4pcs) , 7148 ( USB Cable) , 7170 ( Power cord) , 8307 ( Compact Flash card 128MB) , 8319 ( CF Card reader) , 9125 ( Carrying bag) , PC Software, Batteries × 6, Quick manual Optional accessories : 8124, 8125, 8126, 8127, 8128 ( Load Current Clamp Sensor) . 8129 ( Flexible Clamp Sensor) . 7198 ( Small clips adaptor) . 8312 ( Power supply adaptor) 8322 ( Compact flash card 256MB) 8323 ( Compact flash card 1GB) 9132 ( Carrying case with magnet) Wide range of clamp sensor up to 1000A on request. * PC OUTPUT only * Please refer to here for the CF cards which checked.
Tampilkan Lebih Banyak
Kontak Kami