Back to Top

1
Hi, Guest!
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.
  • KYORITSU 5000/ 5001

KYORITSU 5000/ 5001

Update Terakhir
:
04 / 03 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail KYORITSU 5000/ 5001

KYORITSU 5000/ 5001 Keterangan THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT 60, 000 DATA IS RECORDED 60, 000 data is recorded when 1ch is used and when three all channels are used, 20, 000 data is recorded for each channel - Continuous measurement time • Standard type : About 25 days ( Model 5000) • Long life type : About 40 days ( Model 5001) - Data where it doesn’ t disappear even if battery is consumed Data doesn’ t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. ( warranty for 10 years) - Battery residual display The battery state is displayed by 4 stages. ( When blinking is displayed, it is possible to measure for about one day) - The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software - Selection of one time mode and endless mode • One time on Stop recording when the memory is filled. • One time off ( endless) Overwrite from old data and leave the latest data. - Recall function • The latest 10 data can be checked. • The recall data is Display month and date Display hour and minute Display current value Continuous recording mode : 100mA ( Range) 0 to 100.0mA ( Measurement) ± 1.0% rdg± 5dgt ( Accuracy) ± 2.0% rdg± 10dgt ( Accuracy of sensor combination) 1000mA ( Range) 0 to 1000mA ( Measurement) ± 2.0% rdg± 6dgt ( Accuracy of sensor combination) Event recording mode / The maximum value recording mode : 100mA ( Range) 0 to 100.0mA ( Measurement) ± 1.5% rdg± 7dgt ( Accuracy) ± 2.5% rdg± 12dgt ( Accuracy of sensor combination) 1000mA ( Range) 0 to 1000mA ( Measurement) ± 2.5% rdg± 8dgt ( Accuracy of sensor combination) Capture recording mode : * Accuracy of electric current adjudication is different. For details, refer to the operation manual 100mA ( Range) 0 to 100.0mA ( Measurement) ± 3.0% rdg± 2% fs ( Accuracy) ± 4.0% rdg± 2.5% fs ( Accuracy of sensor combination) 1000mA ( Range) 0 to 1000mA ( Measurement) ± 4.0% rdg± 2% fs ( Accuracy of sensor combination) Operation system : Successive approximation Input : AC Voltage ( AC 100mV/ A) Maximum Circuit Voltage : AC 170mVrms, 250mV Peak value Number of input channel : 3 channels Measurement method : True RMS Measurement interval : 1, 2, 5, 10, 15, 20, 30 sec. / 1, 2, 5, 10, 15, 20, 30, 60 min. Over Range Indication : " OL " mark appears when exceeding measuring range Warning of voltage of battery : Battery mark display of 4 stages Battery life : 5000 : about 25 days on the event record mode ( normal temp. ) 5001 : about 40 days on the event record mode ( normal temp. ) Insulation resistance : 50M© or more Dimensions : 5000 : 111( L) × 60( W) × 36( D) mm 5001 : 111( L) × 60( W) × 42( D) mm Weight : 5000 : about 255g ( include batteries) 5001 : about 315g ( include batteries) The maximum display : 1049 counts Applicable standards : IEC 61010-1: 2001 CAT.III 300V Pollution degree 2 IEC 61326 ( EMC Standard) Power Source : 5000 : Alkaline battery LR6 × 4 5001 : Alkaline battery LR6 × 6 Accessories : Instruction Manual Alkaline battery LR6 Softwear for making graphs ( CD) 7148 ( USB cable) 9118 ( Soft Case) Optional : 7185 ( Extension Cable) 8141 / 8142 / 8143 ( Leakage current clamp sensor) 9119 ( Hard carry case) 9135 ( Carrying bag)
Tampilkan Lebih Banyak
Kontak Kami